A look back at ISCT 2026

ISCT 2026 Recap: Three Days in Montreal

By Fabiana Andrade Melchiori, MD, postdoctoral research fellow at Beth Israel Deaconess Medical Center

The 26th Annual ISCT Symposium brought the CT community together in Montreal from September 17-19, and this year's program reflected just how much the field is shifting at once: from the maturation of photon-counting CT, to AI's usage as a workflow tool, to increasing workload and workforce challenges. Below each day's recap, you'll find related articles tied to that day's themes. Here's a quick day-by-day recap of what tied the meeting together.

Day 1 - Thursday, September 17

The meeting opened with a deep dive into photon-counting CT fundamentals, moving from introductory concepts through oncologic and cardiovascular applications and contrast dose optimization.

The morning's lightning talks gave a rapid-fire look at early-stage research and clinical applications of these developing technologies, ranging from clinical work in critical care and oncologic imaging to more technical, physics-driven studies, including phantom-based work.

The afternoon turned to screening opportunities and their potential: coronary calcium scoring, and opportunistic evaluation of liver disease, bone, and muscle. The challenges of lung cancer screening were also discussed, particularly the persistently low uptake among eligible women compared with mammography. One proposed solution was coordinating lung cancer screening with existing mammography visits, an approach that has shown real promise for improving enrollment. Access was another recurring theme, illustrated by a mobile lung cancer screening program in West Virginia working to reach rural populations for whom screening would otherwise be difficult to obtain.

Up next were the sponsor sessions from Cleerly, GE Healthcare, and Siemens Healthineers, spanning the state of CT technology and a look at its past, present, and future, followed by a session on contrast media safety and supply management.

The day wound down with an opening reception at the Fairmont Queen Elizabeth in downtown Montreal, offering a relaxed setting for attendees to reconnect with familiar faces and meet new colleagues ahead of two more full days of sessions.

Related Reading:

-       Schwartz FR, Sodickson AD, Pickhardt PJ, Sahani DV, Lev MH, Gupta R. Photon-counting CT: technology, current and potential future clinical applications, and overview of approved systems and those in various stages of research and development. Radiology. 2025;314(3):e240662. doi:10.1148/radiol.240662

-       Catania R, Jia L, Haghshomar M, Miller FH, Borhani AA. Detection of moderate hepatic steatosis on contrast-enhanced dual-source dual-energy CT: Role and accuracy of virtual non-contrast CT. Eur J Radiol. 2024;172:111328. doi:10.1016/j.ejrad.2024.111328

-       Lee MH, Zea R, Garrett JW, Summers RM, Pickhardt PJ. AI-based abdominal CT measurements of orthotopic and ectopic fat predict mortality and cardiometabolic disease risk in adults. Eur Radiol. 2025;35(1):520-531. doi:10.1007/s00330-024-10935-w

-       Westerhoff M, Gyftopoulos S, Dane B, et al. Deep Learning-based Opportunistic CT Osteoporosis Screening and the Establishment of Normative Values. Radiology. 2025;317(2):e250917. doi:10.1148/radiol.250917

-       Sandler KL, Godfrey CM, Welty V, et al. Successful Improvement in Lung Screening Enrollment for Women Undergoing Breast Screening-The CALM Study (Coordinate a Lung Screening With Mammography). J Am Coll Radiol. 2025;22(12):1510-1517. doi:10.1016/j.jacr.2025.08.007

-       Pua BB, O'Neill BC, Ortiz AK, et al. Results from Lung Cancer Screening Outreach Utilizing a Mobile CT Scanner in an Urban Area. J Am Coll Radiol. 2024;21(5):778-788. doi:10.1016/j.jacr.2023.10.025

-       Karanth SD, Divaker J, Blair M, et al. Rethinking how mobile units can catalyze progress on lung cancer screening: a scoping review of what we have learned. J Thorac Dis. 2024;16(10):7143-7154. doi:10.21037/jtd-24-846

-       Sertic M, Glazer DI. Guidelines and Controversies of Computed Tomography and Magnetic Resonance Imaging Contrast Media. Radiol Clin North Am. 2025;63(6):849-859. doi:10.1016/j.rcl.2025.03.017

-       Byrne A, Macdonald DB, Kirkpatrick IDC, et al. CAR/CSACI Practice Guidance for Contrast Media Hypersensitivity. Can Assoc Radiol J. 2025;76(3):400-416. doi:10.1177/08465371241311253

Day 2 - Friday, September 18

Day 2 shifted toward implementation and operations. Morning sessions covered practical applications of multi-energy and photon-counting CT across neuro, thoracic, abdominal, musculoskeletal, and pediatric imaging.

The workforce session that followed tackled a set of questions increasingly on every department's mind. Topics included what Gen Z expects from imaging careers, staffing economics, and how to build a 3D post-processing lab, a dedicated space where technologists and research staff prepare reconstructions and advanced imaging studies ahead of time, saving radiologists from having to generate these themselves. The session also took on the globalization of CT recruitment, raising some real ethical questions along the way: since every country needs its own radiologists, simply importing talent from elsewhere isn't a sustainable fix on its own, and even that may not be enough to meet growing demand.

 The afternoon session, "Workflow Under Pressure," addressed rising demand head-on: auto-protocoling, oral contrast necessity, AI tools for radiologist and technologist efficiency, and standardized approaches to CT interventions.

The day wrapped with a session on sustainability in CT, covering iodine recycling, energy consumption, and training.

Related Reading:

-       Douek PC, Boccalini S, Oei EHG, et al. Clinical Applications of Photon-counting CT: A Review of Pioneer Studies and a Glimpse into the Future. Radiology. 2023;309(1):e222432. doi:10.1148/radiol.222432

-       Dane B, Ananthakrishnan L, Marin D, et al. Adult Abdominal Photon-Counting CT Protocols: A Multiinstitutional Consensus of the Society of Abdominal Radiology Photon-Counting Detector CT Emerging Technology Commission. AJR Am J Roentgenol. 2025;225(6):e2533625. doi:10.2214/AJR.25.33625

-       Cook TS, Steingall SJ, Steingall SR, Boonn WW. "Establishing and Running a Three-dimensional and Advanced Imaging Laboratory." RadioGraphics. Published online October 10, 2018. doi:10.1148/rg.2018180058.

-       Malhotra A, Kandala K, Futela D, Payabvash S, Lakhani DA, Gandhi D, Whitlow C, Duszak R. The evolving US radiologist pipeline: trends in residency positions, resident workforce, and practicing radiologists per unit population. J Am Coll Radiol. 2026;23(8):1587-1592. doi:10.1016/j.jacr.2026.04.005

-       Dane B, O'Donnell T, Liu S, et al. Radiation dose reduction, improved isocenter accuracy and CT scan time savings with automatic patient positioning by a 3D camera. Eur J Radiol. 2021;136:109537. doi:10.1016/j.ejrad.2021.109537

-       Kim CR, Sari MA, Grimaldi E, VanderLaan PA, Brook A, Brook OR. CT-guided Coaxial Lung Biopsy: Number of Cores and Association with Complications. Radiology. 2024;313(2):e232168. doi:10.1148/radiol.232168

-       Pillai AK, Kalva SP, Hsu SL, Walker TG, Silberzweig JE, Annamalai G, Baerlocher MO, Mitchell JW, Midia M, Nikolic B, Dariushnia SR, Brook O, et al; Society of Interventional Radiology Standards of Practice Committee. Quality improvement guidelines for mesenteric angioplasty and stent placement for the treatment of chronic mesenteric ischemia. J Vasc Interv Radiol. 2018;29(5):642-647. doi:10.1016/j.jvir.2017.11.024

-       Hadi YH, Hakami AM, Ajeebi AM, et al. Artificial intelligence in radiology workflow: a systematic review into protocol automation and clinical applications. Eur J Radiol Artif Intell. 2026;5:100073. doi:10.1016/j.ejrai.2026.100073

-       Woolen SA, Martin M, Foster CA, MacEachern MP, Maturen KE. Green Imaging: Scoping Review of Radiology's Environmental Impact. J Am Coll Radiol. 2026;23(1):123-135. doi:10.1016/j.jacr.2025.09.013

-       Hernandez AM, Chen AF, Ghatpande O, Omary RA, Woolen S, Jung Y, Fananapazir G. Reducing the energy consumption of magnetic resonance imaging and computed tomography scanners: integrating ecodesign and sustainable operations. J Comput Assist Tomogr. 2025;49(2):191-202. doi:10.1097/RCT.0000000000001700

-       Carver DE, Pruthi S, Struk O, Vigil-Garcia M, Meijer C, Gehrels J, Omary RA, Scheel JR, Thiel CL. "Measuring the Environmental Impact of MRI and CT: A Life Cycle Assessment." J Am Coll Radiol. 2026;23(4):507-518. doi:10.1016/j.jacr.2025.09.030.

 

Day 3 - Saturday, September 19

The final day opened with the Willi Kalender Award announcement, followed by a session on AI in imaging, spanning clinical decision support, general-purpose LLMs in CT workflow, and AI-based reporting. A panel discussion tackled the practical challenges of helping an energy-integrating-detector CT team transition to photon-counting CT. The rest of the day covered protocol optimization (including a look at provincial-scale protocol standardization in Quebec) and a broad session on technical and clinical breakthroughs, from deep learning reconstruction to upright CT, 4D joint imaging, and PCD-based rectal cancer staging. The meeting closed with a wrap-up and the announcement that ISCT 2027 will be held in Tokyo, Japan.

Related Reading:

-       Nassiri MA, Rouleau M, Després P. CT dose reduction: approaches, strategies and results from a province-wide program in Quebec. J Radiol Prot. 2016;36(2):346-362. doi:10.1088/0952-4746/36/2/346

-       Chendeb El Rai M, Beya Far A, Darweesh M, et al. Artificial Intelligence Across the Radiology Workflow: A Nine-Stage Narrative Review. Diagnostics (Basel). 2026;16(10):1485. Published 2026 May 13. doi:10.3390/diagnostics16101485

-       Gress DA, Samei E, Frush DP, et al. Ranking the Relative Importance of Image Quality Features in CT by Consensus Survey. J Am Coll Radiol. 2025;22(1):66-75. doi:10.1016/j.jacr.2024.10.006

-       Caballo M, McLennan L, Benbow M, et al. Quantitative evaluation of an artificial intelligence-assisted platform in CT acquisition workflow. J Med Imaging Radiat Sci. 2026;57(1):102133. doi:10.1016/j.jmir.2025.102133

-       El Sadaney AO, Diehn FE, Rajiah PS, et al. Clinical benefits and current challenges of photon-counting detector CT in vascular imaging. Radiol Adv. 2026;3(3):umag021. Published 2026 Apr 15. doi:10.1093/radadv/umag021

-       Wells JR, Christianson O, Gress DA, et al. The New CMS Measure of Excessive Radiation Dose or Inadequate Image Quality in CT: Issues and Ambiguities-Perspectives From an AAPM-Commissioned Panel. AJR Am J Roentgenol. 2025;224(5):e2432458. doi:10.2214/AJR.24.32458

-       Caballo M, Schuijf JD, Benbow M, Foden A, McLennan L, Condron M, Thomas S, Bull R. Clinical evaluation of a motion correction software based on partial angle reconstruction in coronary CT angiography. Int J Cardiovasc Imaging. 2026;42(6):1145-1158. doi:10.1007/s10554-026-03678-w

Next
Next

CCTA for CTO PCI: A Useful Tool That Remains Underused